COAL ENGINEERING ›› 2014, Vol. 46 ›› Issue (2): 58-59.doi: 10.11799/ce201402020
Previous Articles Next Articles
Received:
Revised:
Online:
Published:
Abstract:
Aim at the gas drainage pump long running, pump body surface and impeller serious rust and corrosion and rust, prone to card pump wait for an accident, there is even twist off pump shaft and burned the danger of motor, which has a serious impact on coal mine gas drainage system stability and safety production. Based on water quality to test and mine rust sample analysis, it is concluded that rust include carbonate and ferric oxide. Using the ratio of oxalate liquid static soak cleaning, and artificial cleaning to remove rust, from the actual effect to see, can achieve the desired cleaning purpose.
Key words: gas drainage pump, derusting, oxalic acid, static soak
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: http://www.coale.com.cn/EN/10.11799/ce201402020
http://www.coale.com.cn/EN/Y2014/V46/I2/58
[1]李晓晖.煤矿井下瓦斯抽放系统中水环真空泵水结垢的防治 [J].煤矿安全,2010,433(11):34-36. [2]马强.瓦斯抽放泵的水垢处理 [J].煤炭技术,2007,26(5):24-25. [3]常文利,张俊,毛秀枝.利用柠檬酸试剂 去除真空泵水垢 [J].矿山机械,2006,34(11):139. [4]徐德胜.水环式真空泵的结垢原因及防范措施 [J].煤矿安全,2002,33(4):19-20.