Abstract:
Although effective volume and empty volume of water sump are important to drainage safety of coal mine, there are seldom study on monitoring them, thus trouble in safety is hidden . This paper, according to the layer phenomenon in water and the structure of water sump, calculated effective volume and empty volume of water sump based on water level and slime thickness, and designed two floats level sensor and float combined with ultrasonic wave level sensor that could detect slime thickness directly or indirectly and water level, which provided reference to apply dynamic monitoring on water sump in coal mine.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: http://www.coale.com.cn/EN/10.11799/ce201406037
http://www.coale.com.cn/EN/Y2014/V46/I6/109
[1] 国家安全生产监督管理总局. 煤矿安全生产规程[M]. 煤炭工业出版社,北京,2011年3月 [2] 孙鹏程. 井下水仓清淤技术研究及关键设备控制[D]. 河北工程大学,2013 [3] 李伟. 矿井水仓煤泥淤积动态监测系统的研究[D]. 中国矿业大学(北京),2012 [4] 潘越,孙鹏程,陈尉,等. 井下水仓煤泥水沉降特性研究[J]. 煤,2013,22(2): 4-5