Coal Engineering ›› 2024, Vol. 56 ›› Issue (10): 231-237.doi: 10.11799/ce202410028

Previous Articles     Next Articles

Application Study of Tubular Microfiltration Membrane in Hard and Silicon Removal of High Saline Water

  

  • Received:2023-10-20 Revised:2024-04-10 Online:2023-10-20 Published:2025-01-16

Abstract: When treating the DTRO concentrated water from Yulin Xiaojihan Coal Mine, tubular microfiltration membrane (TMF) is used instead of the clarifier for solid-liquid separation. Under the condition that the calcium ion concentration of the incoming water is 210 mg/L, the magnesium ion concentration is 221 mg/L, and the total silicon content is 160 mg/L, coagulation is carried out by adding sodium metaaluminate, calcium chloride, magnesium chloride and other agents. Afterwards, the tubular microfiltration membrane is used for solid-liquid separation. The SiO2 removal rate is ≥95%. The effluent meets the requirements of calcium ion concentration ≤10 mg/L, magnesium ion concentration ≤10 mg/L, and total silicon content ≤10 mg/L. And it meets the requirements of reverse osmosis inlet water turbidity ≤ 1 NTU and SDI ≤ 5, Compared to the original process, the operating cost is saved by 10% to 20%.