SVPWM Over-modulation Using 60°coordinate Frame for Three-level Inverter for mine design

  

  • Received:2014-03-20 Revised:2014-05-19 Online:2016-04-10 Published:2016-04-18

Abstract: Aim to reduce the computation of the classical SVPWM over-modulation algorithm for Inverter in Mine Designing,SVPWM Over-modulation using 60°coordinate Frame for Three-level Inverter is proposed in the text. Base on this the new way of over-modulation compare to classical methods is analyzed. At the same time , it is improved to simplify calculation.