煤炭工程 ›› 2019, Vol. 51 ›› Issue (12): 19-23.doi: 10.11799/ce201912004

• 专题论坛 • 上一篇    

超声波检测在副斜井井壁质量探查中的应用#br#
#br#

郑天斌   

  1. 陕西中能煤田有限公司
  • 收稿日期:2019-06-17 修回日期:2019-08-06 出版日期:2019-12-20 发布日期:2020-05-11
  • 通讯作者: 郑天斌 E-mail:498386904@qq.com

Application of Ultrasonic Testing Technology in Detecting the Quality of the Side Wall of the Secondary Inclined Shaft

  • Received:2019-06-17 Revised:2019-08-06 Online:2019-12-20 Published:2020-05-11

摘要: 斜井冻结技术在国内尚无成熟的理论和技术规范,因此对于服役斜井的冻结段井筒质量加以深入研究探查,意义重大。通过采用现阶段广泛应用的超声回弹综合井壁抗压强度进行复核检测,检测值更接近实际。结果表明,井壁及底板混凝土的现时强度较设计值(或初期值)有所下降,井壁裂缝结果检测显示尚未形成贯穿裂缝。检测结果为保证斜井井筒长期安全运行状态评估,提供了可靠依据。

关键词: 超声波, 副斜井, 冻结段井壁, 抗压强度, 超声回弹检测

Abstract: The influence of shaft use on the strength of shaft concrete is slow and continuous. There is no mature theory and technical specification for inclined shaft freezing technology in China. In this paper, the ultrasonic rebound comprehensive method widely used at this stage is adopted to check and test the compressive strength of the shaft wall, and it is found that the current strength of the shaft wall and floor concrete is lower than the designed value (or the initial value), which is not conducive to long-term safe operation and provides reliable basis for the evaluation of shaft safety state.

Key words: ultrasonic, auxiliary inclined shaft, frozen section wall, compressive strength, ultrasonic rebound detection