煤炭工程 ›› 2023, Vol. 55 ›› Issue (4): 173-179.doi: 10.11799/ce202304032

• 研究探讨 • 上一篇    下一篇

砂土层占比对双U型地埋管换热器换热性能影响研究

李磊,徐拴海,张卫东,赵永哲,汪启龙,党东生,沈浩   

  1. 1. 中煤科工西安研究院(集团)有限公司
    2. 中国煤炭科工集团西安研究院工程地质研究所
  • 收稿日期:2022-11-04 修回日期:2022-12-15 出版日期:2023-04-20 发布日期:2023-06-05
  • 通讯作者: 徐拴海 E-mail:xushuanhai@cctegxin.com

Study on the effect of sand-clay layer proportion on heat tranfer performance of double U-shaped buried tube heat exchanger

  • Received:2022-11-04 Revised:2022-12-15 Online:2023-04-20 Published:2023-06-05

摘要: 以西安两处地源热泵项目为工程背景,基于恒热流线热源模型和斜率法,对双U型地埋管换热器(DUBTHE)开展现场岩土热响应试验(TRT),分析了砂土层占比、管径对DUBTHE换热性能的影响。结果表明:当砂层占比分别为16.71%,45.99%时,其岩土初始平均温度、综合导热系数分别为17.70 ℃,1.54 W/(m·K)和18.83 ℃,1.79 W/(m·K)|通过权重法计算的岩土综合导热系数是现场TRT测得的1.15~1.25倍;当砂层占比由16.71%增加到45.99%时,岩土初始平均温度和综合导热系数分别提高了6.38%和16.23%,并随着管径由25 mm增大到32 mm时,夏、冬季单位延米换热量分别提高了12.76%和35.61%|当砂层占比小于45%且地源热泵系统冷热负荷接近时,宜采用DN25 DUBTHE,当砂层占比大于45%且地源热泵系统热负荷大于冷负荷时,宜采用DN32 DUBTHE。

关键词: 地源热泵, 岩土热响应试验, 岩土热物性参数, 换热性能, 砂土层占比

Abstract: It is easy to reduce the service life and heating and cooling efficiency of ground source heat pump system by selecting the inappropriate type of ground heat exchanger. Taking two ground source heat pump projects in Xi'an as the engineering background, based on the constant heat flux line heat source model and the slope method, the influence of sand-clay proportion and pipe diameter on the heat transfer performance of double U-shaped buried tube heat exchanger(DUBTHE) was analyzed through field geotechnical thermal response test(TRT). The results show that the initial average temperature and comprehensive thermal conductivity of rock and soil are 17.70 ℃, 1.54 W/(m·K) and 18.83 ℃, 1.79 W/(m·K) respectively, the proportion of sand layer is 16.71 % and 45.99 %. The comprehensive thermal conductivity of geotechnical soil calculated by the weighting method is 1.15 to 1.25 times of that measured by TRT. When the percentage of sand layer in-creased from 16.71 % to 45.99 %, the initial average temperature and comprehensive thermal con-ductivity of the geotechnical soil increased by 6.38 % and 16.23 %. And with the increase of pipe diameter from 25 mm to 32 mm, the heat exchange per linear meter increased by 12.76 % and 35.61 % in summer and winter, respectively. When the proportion of sand layer is less than 45 % and the cooling and heating load of ground source heat pump system is close, DN25 DUBTHE should be adopted. when the proportion of sand layer is more than 45% and the heating load of ground source heat pump system is higher than the cooling load, DN32 DUBTHE should be adopt-ed. It can provide some reference significance for the design of ground source heat pump system under similar sand-clay proportion conditions.

中图分类号: